DC 640V Battery Charger Discharger Control Switch Undervoltage Overvoltage Protection Board Auto Cut Off Disconnect Controller

UGX 101,594
UGX 175,38042%

In stock

+ shipping from UGX 25,271 to Central Business District
Variation available

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees UGX 25,271
Ready for pickup between 24 May & 29 May when you order within next 10hrs 44mins

Door Delivery

Delivery Fees UGX 32,171
Ready for delivery between 24 May & 29 May when you order within next 10hrs 44mins

Return Policy

Free return within 7 days for eligible items.Details

Seller Information

Sugo Fashion

60%Seller Score

Be the first to follow

Follow

Seller Performance

Order Fulfillment Rate: Excellent

Product details

image

DC 6-40V Battery Charger Discharger Control Switch Undervoltage Overvoltage Protection Board Auto Cut Off Disconnect Controller

Module Highlights:

1. Battery charge and discharge intelligent control;

2. You can set the charge and discharge time;

3. With serial communication function, real-time monitoring of the working status of the relay through the serial port;

4. Additional signal output, when the relay to meet the conditions, the output high, you can control other equipment.

5. A key emergency stop function (STOP on), with reverse protection, reverse does not burn.

Operating mode:

Voltage upper limit: UL1, voltage lower limit nL1, the voltage upper limit is greater than the voltage lower limit (UL1> nL1)

U-1: Charging measurement: When the measured voltage is lower than the lower limit voltage, the relay pulls above; the upper limit voltage, the relay is disconnected.

U-2: charge measurement time control: set the charging time (OP); when the measured voltage is lower than the lower limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage is higher than the upper limit voltage , The relay is disconnected.

U-3: Discharge detection: When the measured voltage is lower than the lower limit voltage, the relay is off, above the upper limit voltage, the relay pulls;

U-4: discharge detection time control: set the discharge time (OP); when the measured voltage is higher than the upper limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage below the lower limit voltage , The relay is disconnected;

U-5: voltage in the range, the relay pull: when the measured voltage between the upper and lower limits, the relay pull, the other circumstances open;

U-6: voltage outside the interval, the relay pull: the measured voltage below the lower limit voltage or higher than the upper limit voltage, the relay pull, the other case the relay is off.

:

1.Power supply voltage: DC6--40V,

2.Voltage detection range DC 0--60V

3.Suitable for le than 60V of the various batteries

4.Voltage measurement error ± 0.1V.

5.Charge and discharge time (OP) range: 0 - 999 minutes.

image

image image

How do I set ?

1. First, according to their needs, to determine the requirements of the work model;

2. According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current mode of operation, the default U-1 mode, and then enter the main interface) pre the SET on for 2 seconds and then release, enter the selection Mode interface, UP, DOWN on to select the mode to be set (U-1 ~ U-6);

3. Ar selecting the mode, aume that we have selected the U-1 mode and pre the SET on to set the corresponding parameter. The parameter to be set will flash (UL1 voltage upper limit, nL1 voltage lower limit, OP conduction time), pre UP, DOWN Key to increase or decrease, you can always pre the key to quickly increase or decrease, pre the SET on to set the current mode of the parameter, the proce above;

4. Set the , and then pre the SET on for 2 seconds to release, the current setting mode will flash, and then return to the main interface, set the of succe!

5. In the main interface, pre the DOWN key to achieve voltage and time switching.

Mode selection interface: pre the SET on for a long time to enter the mode selection interface, set the finished, a long time pre the SET on and then release the exit mode selection interface, back to the main interface.

Additional features:

1. Data upload: through the serial port to achieve data upload, interval 1s upload a voltage and run time, easy to post-data analysis;

2. Serial port settings : You can set the mode and through the serial port, more convenient;

3. An extra signal output, when the relay to meet the conditions, the output high, the other output low.

Serial port control (TTL level communication)

Communication standard:

The baud rate is 115200 bps

Data bits: 8

Stop bit: 1

Check digit: none

Flow control: none

Serial command:

"U-1": Operating mode (range U-1 to U-6)

"000": 0 - does not enable timing function, non-0 - enable timing function (range 001 to 999)

"Dw02.9": Set the lower limit voltage

"Up10.1": set the upper limit voltage (range 00.0V ~ 99.9V)

"Get": Get the current settings

"On": Allows the relay to turn on

"Off": Always turn off the relay

"Start": start uploading data

"Stop": stop uploading data

The above command can be any combination of two, need to be separated by commas

Such as: "dw02.9, up10.1" set the lower limit voltage 02.9V upper limit voltage 10.1V

Upload Status: Test Voltage + On Time + Status

"00.0V, 00: 00: 00, OP \ r \ n"

00.0V: Measured voltage

00:00:00: Relay on time

Status: OP relay on, CL relay off

STOP key function expansion:

Relay enable mode:

1. ON: OP conduction time, the relay allows conduction;

2. OFF: The relay is disabled and is always off;

Pre the STOP on on the main interface to switch between ON and OFF, the current status will flash, and then return to the main interface. (This function is an emergency stop function, a key to disconnect the relay)

Sleep mode:

1. C-P sleep mode: within five minutes, without any operation, the digital tube automatically shut down the display, the program normal operation;

2. O-d normal mode: digital tube is always open display;

Pre and hold the STOP on for 2 seconds to release, to achieve C-P and O-d state of the switch, the current state will flash, and then return to the main interface.

image image image image

image

image image image image image

image image image

About shipping
Shipping and Packaging All it will be double checked and well packed before sending.It will be dispatched within 2 business days ar buyers pay for the order. It usually takes about 14 to 18 working days for delivering the package to the destination(for remote areas,it may take a little longer). 

Special Announcement:
Please fill in the correct and detailed consignee, address and phone number in the order. For fast and correct delivery.If you do not receive order within 30 working days,please feel free to contact Customer Service before leaving Negative and Neutral Feedback, we will do our best to help you resolve the problem.TaxNo, you will only pay what is quoted as total cost at checkout, no more. You are not expected to pay any additional duties ores. If you are asked by Customs or our logistic partner to pay duties, please contact our Customer Service .

Your 100% satisfaction is very ant to us
If the product is not on good condition, You can return this product within 14 working days, please contact customer service center before returning.FeedbackYour satisfaction is our first priorityIf you receive the order and it is in good condition,we would be grateful if you would leave us 5 star Positive Feedback for the transaction.

Specifications

Key Features

  • Origin:Mainland China
  • Condition:New
  • Type:Logic ICs
  • Model Number:Battery Charger Control Module
  • Supply Voltage:DC 6-40V
  • is_customized:Yes
  • Package:SOP
  • Feature 1:Battery Charger Control Module
  • Feature 2:Battery Protection Board
  • Feature 3:Auto Cut Off Battery Charger Module

What’s in the box

1X DC 6-40V Battery Charger Discharger Control Switch Undervoltage Overvoltage Protection Board Auto Cut Off Disconnect Controller

Specifications

  • SKU: FA298IP1QLBLZNAFAMZ
  • Product Line: Fashion
  • Model: BONjicehngdianlu4869
  • Production Country: China
  • Size (L x W x H cm): 10x8x6
  • Weight (kg): 0.2
  • Main Material: PVC