This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
HomeIndustrial & ScientificTest, Measure & InspectElectrical TestingCapacitance & Resistance Meters250W Upgraded Electronic Load Meter 1-100V Input Voltage
UGX 203,560
UGX 407,12050%
In stock
+ shipping from UGX 42,605 to Central Business District
0 out of 5
(No ratings available)Promotions
Delivery & Returns
Shipped from abroad
Choose your location
Pickup Station
Delivery Fees UGX 42,605
Ready for pickup between 24 May & 29 May when you order within next 3hrs 26mins
Door Delivery
Delivery Fees UGX 49,505
Ready for delivery between 24 May & 29 May when you order within next 3hrs 26mins
Return Policy
Free return within 7 days for eligible items.Details
Seller Information
FansWedy
66%Seller Score
37 Followers
Seller Performance
Order Fulfillment Rate: Very Poor
Quality Score: Excellent
Customer Rating: Excellent
Product details
This electronic load meter featuring wide voltage input ranges, it can accept an input voltage of 1-100V, the voltage out of ranges will be indicated by the digital tube flashing and locked with no output. With the real-time current display function, when the output current is greater than 0, the actual working current and regulation current will be displayed alternately, flashing is the actual output current, it is convenient for users to understand the real-time working status of the device. With the automatic correction function, if the voltage and current deviation are found to be more than the specified value during the production test, it can be automatically corrected by simple operation to ensure the accuracy of the equipment.
Features:
Featuring wide voltage input ranges, it can accept an input voltage of 1-100V, the voltage out of ranges will be indicated by the digital tube flashing and locked with no output.
The lock function allows you to lock the as needed. For example, the input is 100 V, the output current is not more than 1 A, and the software locks have nothing to do with the current adjustment knob.
With the real-time current display function, when the output current is greater than 0, the actual working current and regulation current will be displayed alternately, flashing is the actual output current, it is convenient for users to understand the real-time working status of the device.
With the temperature protections function, when the NTC temperature probe accesses the voltage digital tube will alternately display the input voltage and temperature (the probe needs to be fixed in the heat sink or MOS tube) when the temperature exceeds 80℃, and the current will be lowered to stop the output, to protect the safety of the equipment. Below 50 degrees to re-open, and the temperature protections will be invalid without access to the probe.
With the fan delay-off function, when the current regulation is adjusted to 0, the fan will be delayed off for 1 minute.
With the automatic correction function, if the voltage and current deviation are found to be more than the specified value during the production test, it can be automatically corrected by simple operation to ensure the accuracy of the equipment.
Simple operation, when shutting down, you need to disconnect the input current first, and then shut down the 12 V powersupply of the electronic load, to avoids the EMF burning the MOS tube.
Although the RS485 communication function is not turned on at present, this function is reserved to provide the possibility of prospect upgrades and expansion.
Specifications:
Name: Electronic Load Meter
Material: plastics
: 100W, 250W (optional)
Package size: 120 * 130 * 145mm / 4.72 * 5.12 * 5.71in
Package weight: 500g / 1.10lb
Packing List:
1 * Electronic Load Meter
1 * Cable
1 * Nut
Features:
Featuring wide voltage input ranges, it can accept an input voltage of 1-100V, the voltage out of ranges will be indicated by the digital tube flashing and locked with no output.
The lock function allows you to lock the as needed. For example, the input is 100 V, the output current is not more than 1 A, and the software locks have nothing to do with the current adjustment knob.
With the real-time current display function, when the output current is greater than 0, the actual working current and regulation current will be displayed alternately, flashing is the actual output current, it is convenient for users to understand the real-time working status of the device.
With the temperature protections function, when the NTC temperature probe accesses the voltage digital tube will alternately display the input voltage and temperature (the probe needs to be fixed in the heat sink or MOS tube) when the temperature exceeds 80℃, and the current will be lowered to stop the output, to protect the safety of the equipment. Below 50 degrees to re-open, and the temperature protections will be invalid without access to the probe.
With the fan delay-off function, when the current regulation is adjusted to 0, the fan will be delayed off for 1 minute.
With the automatic correction function, if the voltage and current deviation are found to be more than the specified value during the production test, it can be automatically corrected by simple operation to ensure the accuracy of the equipment.
Simple operation, when shutting down, you need to disconnect the input current first, and then shut down the 12 V powersupply of the electronic load, to avoids the EMF burning the MOS tube.
Although the RS485 communication function is not turned on at present, this function is reserved to provide the possibility of prospect upgrades and expansion.
Specifications:
Name: Electronic Load Meter
Material: plastics
: 100W, 250W (optional)
Package size: 120 * 130 * 145mm / 4.72 * 5.12 * 5.71in
Package weight: 500g / 1.10lb
Packing List:
1 * Electronic Load Meter
1 * Cable
1 * Nut
Specifications
Key Features
- Featuring wide voltage input ranges, it can accept an input voltage of 1-100V, the voltage out of ranges will be indicated by the digital tube flashing and locked with no output.
- The lock function allows you to lock the as needed. For example, the input is 100 V, the output current is not more than 1 A, and the software locks have nothing to do with the current adjustment knob.
- With the real-time current display function, when the output current is greater than 0, the actual working current and regulation current will be displayed alternately, flashing is the actual output current, it is convenient for users to understand the real-time working status of the device.
- With the temperature protections function, when the NTC temperature probe accesses the voltage digital tube will alternately display the input voltage and temperature (the probe needs to be fixed in the heat sink or MOS tube) when the temperature exceeds 80℃, and the current will be lowered to stop the output, to protect the safety of the equipment. Below 50 degrees to re-open, and the temperature protections will be invalid without access to the probe.
- With the fan delay-off function, when the current regulation is adjusted to 0, the fan will be delayed off for 1 minute.
- With the automatic correction function, if the voltage and current deviation are found to be more than the specified value during the production test, it can be automatically corrected by simple operation to ensure the accuracy of the equipment.
What’s in the box
1 x Electronic Load Meter,1 x Cable,1 x Nut
Specifications
- SKU: GE779IP37LVGNNAFAMZ
- Model: N/A
- Production Country: China
- Size (L x W x H cm): 14.50×13.00×12.00
- Weight (kg): 0.50
- Color: Multicolor
Customer Feedback
This product has no ratings yet.
250W Upgraded Electronic Load Meter 1-100V Input Voltage
UGX 203,560
UGX 407,12050%
Questions about this product?