product_image_name-Generic-LED Electric Unit Digital Iron Station Temperature Controller DIY Kits usefor HAKKO T12 Handle vibration switch Set 1-1product_image_name-Generic-LED Electric Unit Digital Iron Station Temperature Controller DIY Kits usefor HAKKO T12 Handle vibration switch Set 1-2product_image_name-Generic-LED Electric Unit Digital Iron Station Temperature Controller DIY Kits usefor HAKKO T12 Handle vibration switch Set 1-3product_image_name-Generic-LED Electric Unit Digital Iron Station Temperature Controller DIY Kits usefor HAKKO T12 Handle vibration switch Set 1-4product_image_name-Generic-LED Electric Unit Digital Iron Station Temperature Controller DIY Kits usefor HAKKO T12 Handle vibration switch Set 1-5product_image_name-Generic-LED Electric Unit Digital Iron Station Temperature Controller DIY Kits usefor HAKKO T12 Handle vibration switch Set 1-6product_image_name-Generic-LED Electric Unit Digital Iron Station Temperature Controller DIY Kits usefor HAKKO T12 Handle vibration switch Set 1-7

Share this product

Shipped from abroad

LED Electric Unit Digital Iron Station Temperature Controller DIY Kits usefor HAKKO T12 Handle vibration switch Set 1

UGX 271,900
UGX 468,79342%

In stock

+ shipping from UGX 50,123 to Central Business District

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees UGX 50,123
Ready for pickup between 22 June & 27 June when you order within next 10hrs 49mins

Door Delivery

Delivery Fees UGX 52,123
Ready for delivery between 22 June & 27 June when you order within next 10hrs 49mins

Return Policy

Free return within 7 days for eligible items.Details

Seller Information

SFHOMIE Store

New Seller

20 Followers

Follow

Seller Performance

This seller does not have enough history for us to evaluate his performance yet

Product details

This product is QUICKO T12 DIY Kit , not HAKKO product, you need to prepare a power supply and aemble the parts together by yourself. if you are not good at DIY, or if you know little about Electricity, please this kits. We do not aume any responsibility for man-made damages. Thank you for your understanding. PLEASE WATCH THE NEWEST DIY ABOVE THIS PAGE BEFORE MAKE AN ODER ! PLEASE WATCH THE NEWEST DIY ABOVE THIS PAGE BEFORE MAKE AN ODER! PLEASE WATCH THE NEWEST DIY ABOVE THIS PAGE BEFORE MAKE AN ODER!

ant things say three times!

Please use the 24V3A power supply to drive the controller!

image image image image image image image image image image image image image image image

PLEASE WATCH THE NEWEST DIY ABOVE THIS PAGE, YOU CAN ALSO REFERENE TOTHE FOLLOWING OLD DIY STEPS

image image image image image image image image image image image image image image image image

Controller setting mode:

(The default has been set, no special requirements, please do not set up a )

Pre and hold the encoder on does not move → start → enter the settings mode:

There are 12 menus available for setup,P00,P01,P02,P03,P04,P05,P06,P07,P08,P09,P10,P11.The digital display menu is 1.5 seconds,and then automatically displays the corresponding s of this menu,at the same time rotate left encoder is reduced,right is increase,Pre it and automatically save the currently set s.And then display the menu for 1.5 seconds, and then display the corresponding s of this menu, and so on. When all s are set to automatically enter the normal heating mode.

Because each set a to save once, so you can shut down at any time without having to set all the s (such as you just want to set P01, set P01 after you can shut down and then boot into normal mode)

Menu item:

P00: restore the default s (0 or 1, the default value of 0,0 for not recovering, 1 for the recovery)

P01: Operational amplifier gain (200 to 350 times, step 1, default 230)

P02: Operational amplifier offset voltage (0 ~ 250mV, step 2, the default value of 100, refers to the tto keep the room temperature operational amplifier inherent output voltage, according to my measurement this voltage varies greatly with temperature, different magnification Not the same, the higher the magnification, if you do not measure, please keep the default value)

P03: thermocouple ℃ / MV data (30 ~ 50, step 1, the default value of 41, refers to the thermocouple need to temperature how much voltage was increased by 1mV, according to the type of thermocouple self-calculation, if you do not understand, please keep Defaults)

P04: temperature adjustment step (0,1,2,5,10 degrees optional, 0 can lothe temperature)

P05: sleep time (how long don’t not move into sleep) (0 ~ 60 minutes, step 1, 0 is to forbidden the sleep function)

P06: Shutdown time (0 ~ 180 minutes, 0 ~ 30 step 1,30 ~ 180 step 10, 0 is forbidden shutdown function)

P07: temperature correction (+20 degrees, step 1) (due to NTC resistance in the chais, the station heat will lead to the detection of NTC temperature higher than room temperature, resulting in high temperature compensation of the thermocouple, temperature is not accurate,or other causes the temperature is not accurate.If you set the other s are correct value but the temperature is still high or low, you can use this correction.For example, to detect the displayed temperature is 20 degrees higher than the actual value of this Set to 20)

P08: wake mode (0,1, 0 in the shutdown mode can be rotated the encoder and also can shake the handle to wake up, 1 can only rotate the encoder wake up (Note: pre the encoder can not wake up, can only rotate) )

P09: temperature increase mode to increase the temperature to adjustable (20 degrees to 100 degrees adjustable, adjust the pace of 10 degrees)

P10: temperature to increase the duration to adjustable (adjustment range of 10 seconds to 250 seconds, adjust the step 5 seconds)

P11: setting mode Auto save and return to heating mode Function to active time adjustable (range 4 seconds to 60 seconds)

Installed Note: 1. Strictly reference shop tutorials, well insulated and grounded against static electricity. 2. Before power test, carefully chethe wiring is correct, whether Weld and short, full power test machine after confirmation. 3. connect 12-24V DC, if received more than 20V power supply,2017 new style productdon't need to remove anything! 4. When you configure the power supply voltage and current requirements thelves refer to the following table: Power (third column) is determined by the voltage (first column), as long as the current reaches the minimum current (second column). Measuring Machine normal, lights and display status: 1. Unplugged T12 tip, turn the light flashed off, show SER, 1 seconds after the display 500. 2. T12 plug tip, boot light uniform flashing, indicating rapid heating from room temperature generally show the set temperature to rise, approaching the set temperature, strobe lights. Indicator is not flashing or intermittent fl, indicating that the ttemperature reaches the set temperature or alternating temperature compensation. When measuring machines on display digital bounce questions: Because with the new T12 tip, the tinside the heater did not burnt, it will be just a little jump start with warm, generally do not need special treatment, the natural use of 1-2 days basically not bounce up. If you need effective immediately, the general recommendations of the temperature to 350 ?-380 ?while heating to the point of tin head, burning off after 4-5 minutes, until the tto cool before you can reboot! (1 no action can be repeated 2-3 times) STC-T12 Digital Station DIY kits/MINI STC-LED-T12 solder DIY Unit sets /T12 LED Temperature Controller Kits

About shipping
Shipping and PaAll itwill be double checked and well packed before sending.Itwill be dispatched within 2 business days after buyers pay for the order. It usually takes about 14 to 18 working days for delivering the package to the destination(for remote areas,it may take a little longer). 

Special Announcement:
Please fill in the correct and detailed consignee, address and phone number in the order. For fast and correct delivery.If you do not receive order within 30 working days,please feel free to contact Customer Service before leaving Negative and Neutral Feedback, we will do our best to help you resolve the problem.TaxNo, you will only pay what is quoted as total cost at checkout, no more. You are not expected to pay any additional duties or taxes. If you are asked by Customs or our logistic partner to pay duties, please contact our Customer Service .

Your 100% satisfaction is very ant to us
If the product is not on good condition, You can return this product within 14 working days, please contact customer service center before returning.FeedbackYour satisfaction is our first priorityIf you receive the order and it is in good condition,we would be grateful if you would leave us 5 star Positive Feedbafor the transaction.

Specifications

Key Features

  • Origin:CN(Origin)
  • Certification:NONE
  • Model Number:STC-LED-T12
  • Dimensions:null
  • Temperature Stability:plus or minus 10C
  • Input Voltagle:24V
  • Output Power:MAX 72W
  • Output Temperature:200C-450C
  • Dea Tip:T12-k
  • Package:carton

What’s in the box

1X QUICKO LED Electric Unit Digital Station Temperature Controller DIY Kits usefor HAKKO T12 Handle vibration switch

Specifications

  • SKU: GE779IP1DW6Y6NAFAMZ
  • Model: sfhodianlaotie3569
  • Production Country: China
  • Size (L x W x H cm): 10x8x6
  • Weight (kg): 0.3
  • Color: Set 1
  • Care Label: No direct sundlight, cleaning with low percentage alcohol

Customer Feedback

This product has no ratings yet.

LED Electric Unit Digital Iron Station Temperature Controller DIY Kits usefor HAKKO T12 Handle vibration switch Set 1

LED Electric Unit Digital Iron Station Temperature Controller DIY Kits usefor HAKKO T12 Handle vibration switch Set 1

UGX 271,900
UGX 468,79342%
Questions about this product?

Recently Viewed

See All